Separate box type resistance furnace installation, use and maintenance

1.1 Electric furnace does not need special installation, just lay it on the indoor floor or on the platform. The controller should be placed on the workbench with a slope of no more than 5 degrees. The minimum distance of the controller from the electric furnace shall not be less than 0.5 m. The controller should not be placed on the electric furnace to avoid affecting the normal operation of the controller.

1.2 The power supply line connecting the controller and the electric furnace, the load capacity of the switch and the fuse should be slightly larger than the rated power of the electric furnace.

1.3 When wiring, first loosen the screws on the left and right sides of the controller casing, then turn the casing up and connect the power cable as shown. Connection of the controller to the electric furnace and thermocouple connection (preferably using compensation wires). The thermocouple is inserted into the furnace from the small hole of the thermocouple holder, and the gap between the hole and the thermoelectric is blocked by the asbestos rope, and then fixed. (Note: the phase of the power supply is not reversed from the neutral line. For operational safety, both the controller and the electric furnace must be grounded reliably)

1.4 Check the wiring is correct, you can power on, first close the power switch, then pull the button switch on the controller panel to the open position, adjust the setting button, set the temperature to the degree you need, if Set the switch to the measuring position, the red light is off (NO), there is also the sound of the contactor, the electric furnace is energized, the ammeter indicates the heating current value, and the temperature rises slowly as the temperature inside the furnace rises, indicating that the work is normal. When the temperature rises to the set required temperature, the red light is off (NO), the green light is on (YES), the electric furnace is automatically powered off, and the temperature rise is stopped. Later, when the temperature in the furnace drops slightly, the green light is off and the red light is on. The electric furnace is automatically energized again. The cycle is repeated to achieve the purpose of automatically controlling the temperature inside the furnace.

1.5 In order to check whether the breaker protection device works normally, the method is: loosen one end of the thermocouple, and the temperature measurement indicator rises rapidly to the highest point, and the heating power supply is automatically cut off, then the device is good, and the thermocouple is reconnected. , can work normally.

1.6 Oven, when the electric furnace is used again after the first use or long-term deactivation, the oven must be carried out. The process is as follows:

When the room temperature rises to 200 ° C for 4 hours (open the furnace door to allow water vapor to emanate) when 200 ° C to 600 ° C for 4 hours (close the furnace door) when 600 ° C to 800 ° C 2 hours (close the furnace door)

1.7 After use, first pull the toggle switch on the control panel to the off position, then turn off the main power switch.

Maintenance

2.1 The controller should be placed in a place with good dryness and ventilation, no corrosive gas, the working environment temperature is -10-50 °C, and the relative humidity is not more than 85%.

2.2 In order to ensure accurate measurement, the temperature difference meter of XMT type temperature controller is calibrated every year by DC potential difference meter to avoid large error.

2.3 Regularly check whether the wiring of each part is loose, and the contact of the AC contactor is good. If the fault occurs, it should be repaired in time.

Tips

1. Do not exceed the maximum temperature of the resistance furnace when using.

2. Always cut off the power supply when handling the sample to prevent electric shock.

3. When opening the sample, the opening time of the furnace door should be as short as possible to prolong the service life of the electric furnace.

4. It is forbidden to infuse any liquid into the furnace.

5. Do not put the sample with water and oil into the furnace; do not use the clip with water and oil to take the sample.

6. Wear special gloves when handling samples to prevent burns.

7, the sample should be placed in the middle of the furnace, neatly placed, do not put it.

8. Do not touch the electric furnace and surrounding samples.

9. Cut off the power and water source after use.

10. The resistance furnace shall not be operated without the permission of the management personnel, and shall be operated in strict accordance with the operating procedures of the equipment.

Global hardware network

Concerned about surprises

Label: Separate box type resistance furnace installation and maintenance

Previous: Rubber plant separation from the dust collector solution Next: Heat exchanger equipment use and maintenance

About High Speed Door Accessories:

1.Driving system: High Speed Door Servo System motor and control, motor SNMA / SEJ +reducer+flang+encoder+control box

2.Other accessories: Middle aluminium bar, bottom aluminium bar, aluminium vertical track, stainless steel vertical track, brushes,round nylon strip, PVC roll, rolling steel tube complete, drum be;;s for rolling tube, side end covers, stainless steel cover, steel tubes, air bag sensor system, safety light beam, Microwave sensor 24 Gigahertz,PVC welding machine, smoke and fire sensors, PVC transparent window, magnetic loop, photocell, remote control, manual push button, sound warning alarm Led lamp traffic light

 For some main accessories, here is detain introduction:

1).24G radar sensor:

Brand: Hofic

Technology: Microwave processor

Maintain time: 0.5s

Protection: IP54

Transmitting frequency: 24.125GHz

Maximum installation height: <5meter

Transmitting power density: <5mw/cm2

Power consumption: <1W(VA)

Installation angle: 0-90°(lengthways) -30-30°(crosswise)

Supply voltage: AC&DC 12V-30V

2).Photocell:

Approval CE & ISO9001

Power supply AC/DC 12-30V

Static current 25A

Action current 40mA

Mounting distance Max 10m

NO or NC contact Done by NO./NC. contact selection              

Working environment temperature -42℃ to +45℃

Working environment humidity 10 to 90%RH

Appearance dimensions( controller) 123*50*32mm(L*W*H)

Appearance dimensions(Magic eye head) 19*13mm(L*D)

3). Remote control

Operating Voltage: AC220V/50HZ+-20%

Transmit power:≤100mW;Super regenerative module, strong anti-interference

Operating temperature:-30℃-+70℃

Working frequency: 433MHZ;transmitter 1527, millions of encoding chip

Accept sensitivity:≤110dB

Manipulation method: electric remote control

Configure the quantity: Wireless number; factory configuration transmitter two. Can be equipped with PT2272 digital decoder chip

Configure the function: Up, down, stop, anti-lock full-featured reproduction

4). Magnetic loop

Voltage: 12V AC/DC +-10% 24V 115V AC+-10% 230V

Power: <2VA

Continued electrical output: 7A / 250V AC

Frequency range: 20 to 200K Hz

Response time: infinity (factory setting) or adjust maintain time

Sensitivity: 0.01% to 0.1% divided into 3 levels

Protection level: IP30

Electromagnetic compatibility (EMC) Complies with EM50081-1 and EN50082-2

Detection loop inductance: the limit of 40uH to 100uH ideal value 80uH to 300uH

Operating temperature: -25 ℃ to 70 ℃

Storage temperature: -40 ℃ to 85 ℃

Relative humidity: <90% non-condensing

Temperature compensation: automatic compensation up to 50 ℃ / h

Connection type: 11 pin DIN rail socket

Dimensions: 41 * 78 * 85 mm (width * height * length)

Weight: 250 grams

5). manual push button

This exit switch button is made of ABS and has built-in indicator light make it looks more elegant and fashionbale. It can be widely used in public entrance gates, public door, home, office, hotel, etc.

Door Exit Button Push To Exit Switch Door Opener For Access Control  Security

Main Feature

Fashionable appearance

Made of ABS Plastic

Easy to install and operate

Used for access control

Specification

Mechanical Life: 500,000 test

Material: Plastic

6). Limit switch encoder

Voltage: DC5V-24V

Output voltage: high voltage≥85%Vcc, low voltage≤0.5V

Maximum mechanical speed:6000rpm

Anti-vibration: 50m/s,10-200HZ,XYZeach way 2 times.

Current consumption:≤30mA

Response frequency: 0-100KHZ

Protection: waterproof,oil proof,dust prevention, IP54

The output code system: binary code

Operating life: MTBF≥30000(+25℃,2000rpm)

Rotational inertia:4.0x10-8kgm²

Maximum load:radial direction20N

Axial direction:10N

Weight: about 0.4kg

High Speed Door Accessories

High Speed Door Accessories,High Speed Door,Electronic High Speed Door Accessories

Shenzhen Hongfa Automatic Door Co., Ltd. , https://www.hongfadoor.com