Rotary vane vacuum pump failure and treatment methods

2XZ-type rotary vane vacuum pump failure and its elimination method: (I), 2XZ-type rotary vane vacuum pump ① oil level is too high, you can enter excess oil. ② mist reducer pump oil or debris, should be removed. ⑵, 2XZ rotary vane vacuum pump back to the ① check valve is not closed, after stopping the pump, the oil level dropped quickly, and then re-open and then stop to observe changes or open inspection. ② The two pump cover seal improper assembly or wear, can be exchanged. ③ pump cover or pump plane is not flat, can be trimmed. ④ exhaust valve damage, should be exchanged. Note: Check the pump ultimate vacuum to compression mercury vacuum gauge shall prevail. (3), 2XZ type rotary vane vacuum pump leakage ① drain plug, tank gasket or improper assembly, screw tightening; ② oil tighten, plexiglass overheating deformation; ③ 2XZ rotary vane vacuum pump body parts and support connections The gasket is not well pad; improper assembly or wear oil seal; should be adjusted or replaced. Iv, 2XZ type rotary vane vacuum pump noise ① rotary blade spring break, you can change the spring. ② Burr, dirt or deformation, the operation of obstacles, should check the grinding cleaning. ③ bearing wear, wear parts. Should be trimmed or replaced. ④ motor problems, should be checked. ㈤, 2XZ rotary vane vacuum pump is not high vacuum and its elimination ① oil level is too low, there is a large exhaust sound, you can add a clean vacuum pump oil. ② pump oil for condensable steam pollution, gas can be opened town clean or replace the new oil. ③ 2XZ rotary vane vacuum pump external pipes, containers, test instrumentation pipes, fittings and other leaks. Big leak, there is a large exhaust sound, exhaust vent vent, should find the leak site, to eliminate. ④ intake nozzle or gas seal rubber seal diagram improper assembly, damage or aging, should be adjusted or replaced. ⑤ 2XZ-type rotary vane vacuum pump inlet hole plugged, can be set aside into the oil nozzle, clear the hole. ⑥ serious pollution of the vacuum system, including containers, pipes, etc., should be cleaned. ⑦ 2XZ-type rotary vane vacuum coil spring break, should be replaced. ⑧ rotary blade, pump or pump cover wear, the gap is too large, should be checked, trimmed or replaced. ⑨ pump temperature is too high, should improve ventilation and cooling. If the pumping gas temperature is too high, it should be cooled before entering the pump.

Magnetic Badge

Magnet Badges,Steelmagnet Badge,Magnetic Badge

YangYi Magnetics Co., Ltd. , http://www.hz-magnets.com

Posted on